Volume 35, Issue 3 , Pages 565-577, 1 June 1996
Shape recovery and volume calculation from biplane angiography in the stereotactic radiosurgical treatment of arteriovenous malformations
Abstract
: A model for calculating the three-dimensional volume of arteriovenous malformations from biplane angiography.
: Three-dimensional (3D) volume reconstruction is easily feasible with axial, coronal, or sagittal computer tomography (CT) and nuclear magnetic resonance (NMR) scans. On the other hand, radiosurgicals treatment of arteriovenous malformations (AVM) is exclusively based on two orthogonal stereotactic projections, obtained with angiographic procedures. Most commonly, AVM volumes have been calculated by assimilating the nidus volume to a prolate ellipsoid. We present an algorithm dedicated to 3D structure reconstruction starting from two orthogonal stereotactic projections. This has been achieved using a heuristic approach, which has been widely adopted in the artificial intelligence domain.
: Tests on phantom of different complexity have shown excellent results.
: The importance of the algorithm is considerable. As a matter of fact: (a) it allows calculations of complex structures far away from regular ellipsoid; (b) it permits shape recovery; (c) it provides AVM visualization on axial planes.
Keywords: Gamma knife radiosurgery, AVM, Isodose volumes, 3D reconstruction
No full text is available. To read the body of this article, please view the PDF online.
To access this article, please choose from the options below
PII: S0360-3016(96)80020-4
© 1995 Published by Elsevier Inc.
Volume 35, Issue 3 , Pages 565-577, 1 June 1996