International Journal of Radiation Oncology * Biology * Physics
Volume 48, Issue 4 , Pages 983-989, 1 November 2000

CT-targeted irradiation of the breast and internal mammary lymph nodes using a 5-field technique

  • Rufus A Scrimger, M.D.

      Affiliations

    • Department of Radiation Oncology, Cross Cancer Institute, Edmonton, Alberta, Canada
    • Corresponding Author InformationReprint requests to: Dr. Rufus A. Scrimger, Department of Human Oncology, K4/B100 CSC, 600 Highland Avenue, Madison, WI 53792
  • ,
  • Sherry G Connors (M.Sc.)

      Affiliations

    • Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta, Canada
  • ,
  • Steven B Halls, M.D.

      Affiliations

    • Department of Oncologic Imaging, Cross Cancer Institute, Edmonton, Alberta, Canada
  • ,
  • Adalei A Starreveld, M.D.

      Affiliations

    • Department of Radiation Oncology, Cross Cancer Institute, Edmonton, Alberta, Canada

Accepted 9 June 2000.

Abstract 

Purpose: To develop an effective and resource-efficient radiotherapy technique to treat the breast and regional nodes, including the ipsilateral internal mammary nodes.

Methods and Materials: Eighty female patients who underwent MRI scans for a variety of indications had coronal, T1-weighted images of the chest performed to determine the position of the internal mammary chain (IMC). Based on these results, a 5-field treatment technique was developed that would include the breast, supraclavicular fossa, and ipsilateral IMC, while maintaining a low dose to the heart, lungs, and contralateral breast. This technique was implemented in a cohort of 13 patients.

Results: The lateral position of the right and left IMC were measured in three cephalo-caudad positions: at the clavicular heads, upper manubrium, and midsternum (at the 2nd/3rd rib interspace). The mean lateral separation between the right and left IMC chains at each level (and 95% confidence interval) at each level were 5.8 cm (4.67–7.00), 5.6 cm (4.49–6.73), and 5.9 cm (4.66–7.19), respectively. Treatment was delivered to 13 patients using a 5-field technique, with tangential photon fields for the breast, anterior and posterior supraclavicular/axillary field, and a matching anterior electron field. Three-dimensional treatment planning of a representative case confirmed adequate coverage of the planning target volume (PTV). The median dose to the whole heart was 10 Gy, and 20% of the ipsilateral lung received more than 20 Gy. Seven of the 13 patients treated experienced moist desquamation at the junction of the electron field and breast tangents, and 1 patient had persistent ulceration at 3 months’ follow-up.

Conclusion: The 5-field technique described in this paper provides good coverage to the breast and regional nodes with acceptable toxicity, and without requiring three-dimensional treatment planning or intensity-modulated radiotherapy techniques.

Keywords:  Breast cancer, Radiation therapy, Internal mammary lymph nodes

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 30.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0360-3016(00)00738-0

International Journal of Radiation Oncology * Biology * Physics
Volume 48, Issue 4 , Pages 983-989, 1 November 2000