International Journal of Radiation Oncology * Biology * Physics
Volume 53, Issue 2 , Pages 261-268 , 1 June 2002

Intrafraction prostate motion during IMRT for prostate cancer

  • Eugene Huang, B.S

      Affiliations

    • Division of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
  • ,
  • Lei Dong, Ph.D.

      Affiliations

    • Division of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
  • ,
  • Anurag Chandra, M.D.

      Affiliations

    • Division of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
  • ,
  • Deborah A Kuban, M.D.

      Affiliations

    • Division of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
  • ,
  • Isaac I Rosen, Ph.D.

      Affiliations

    • Division of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
  • ,
  • Anissa Evans (R.T.T.)

      Affiliations

    • Division of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
  • ,
  • Alan Pollack, M.D., Ph.D.

      Affiliations

    • Corresponding Author InformationReprint requests to: Alan Pollack, M.D., Ph.D., Department of Radiation Oncology, Fox Chase Cancer Center, 7701 Burholme Ave., Philadelphia, PA 19111 USA. Tel: (215) 728-2940; Fax: (215) 728-2868
    • Division of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA

Received 26 June 2001 ,Revised 27 December 2001 ,Accepted 7 January 2002.

References 

  1. Langen KM, Jones DTL. Organ motion and its management. Int J Radiat Oncol Biol Phys. 2001;50:265–278
  2. Balter JM, Sandler HM, Lam K, et al.  Measurement of prostate movement over the course of routine radiotherapy using implanted markers. Int J Radiat Oncol Biol Phys. 1995;31:113–118
  3. Crook J, Salhani D, Lam K, et al.  Measurement of prostate movement over the course of routine radiotherapy using implanted markers. Radiother Oncol. 1995;37:35–42
  4. Sandler HM, Bree RL, McLaughlin PW, et al.  Localization of the prostatic apex for radiation therapy using implanted markers. Int J Radiat Oncol Biol Phys. 1993;27:915–919
  5. Shimizu S, Shirato H, Kitamura K, et al.  Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. Int J Radiat Oncol Biol Phys. 2000;48:1591–1597
  6. Vigneault E, Pouliot J, Laverdiere J, et al.  Electronic portal imaging device detection of radiopaque markers for the evaluation of prostate position during megavoltage irradiation (A clinical study). Int J Radiat Oncol Biol Phys. 1997;37:205–212
  7. Antolak JA, Rosen II, Childress CH, et al.  Prostate target volume variations during a course of radiotherapy. Int J Radiat Oncol Biol Phys. 1998;42:661–672
  8. Beard CJ, Kijewski P, Bussiere M, et al.  Analysis of prostate and seminal vesicle motion (Implications for treatment planning). Int J Radiat Oncol Biol Phys. 1996;34:451–458
  9. Melian E, Mageras GS, Fuks Z, et al.  Variation in prostate quantification and implications for three-dimensional conformal treatment planning. Int J Radiat Oncol Biol Phys. 1997;38:73–81
  10. Roach M, Faillace-Akazawa P, Malfatti C. Prostate volumes and organ movement defined by serial computerized tomographic scans during three-dimensional conformal radiotherapy. Radiat Oncol Invest. 1997;5:187–194
  11. Rudat V, Schraube P, Oetzel D, et al.  Combined error of patient position variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer. Int J Radiat Oncol Biol Phys. 1996;35:1027–1034
  12. Zelefsky MJ, Crean D, Mageras GS, et al.  Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy. Radiother Oncol. 1999;50:225–234
  13. Zellars RC, Roberson PL, Straderman M, et al.  Prostate position late in the course of external beam therapy (Patterns and predictors). Int J Radiat Oncol Biol Phys. 2000;47:655–660
  14. Lattanzi J, McNeely S, Hanlon A, et al.  Daily CT localization for correcting portal errors in the treatment of prostate cancer. Int J Radiat Oncol Biol Phys. 1998;41:1079–1086
  15. Lattanzi J, McNeeley S, Pinover W, et al.  A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer. Int J Radiat Oncol Biol Phys. 1999;43:719–725
  16. Lattanzi J, McNeeley S, Hanlon A, et al.  Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer. Urology. 2000;55:73–78
  17. Ten Haken RK, Forman JD, Heimburger DK, et al.  Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladder. Int J Radiat Oncol Biol Phys. 1991;20:1317–1324
  18. Padhani AR, Khoo VS, Suckling J, et al.  Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. Int J Radiat Oncol Biol Phys. 1999;44:525–533
  19. van Herk M, Bruce A, Kroes A, et al.  Quantification of organ motion during conformal radiotherapy of the prostate by three-dimensional image registration. Int J Radiat Oncol Biol Phys. 1995;33:1311–1320
  20. Stroom JC, Kroonwijk M, Pasma KL, et al.  Detection of internal organ movement in prostate cancer patients using portal images. Med Phys. 2000;27:452–461
  21. Dawson LA, Litzenberg DW, Brock KK, et al.  A comparison of ventilatory prostate movement in four treatment positions. Int J Radiat Oncol Biol Phys. 2000;48:319–323
  22. Malone S, Crook JM, Kendal WS, et al.  Respiratory-induced prostate motion (Quantification and characterization). Int J Radiat Oncol Biol Phys. 2000;48:105–109