International Journal of Radiation Oncology * Biology * Physics
Volume 53, Issue 3 , Pages 566-573, 1 July 2002

Measurement of lung tumor volumes using three-dimensional computer planning software

  • Patrick Bowden, M.B. B.S. (F.R.A.N.Z.C.R.)

      Affiliations

    • Division of Radiation Oncology, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • Richard Fisher, M.B. B.S., Ph.D.

      Affiliations

    • Statistical Centre, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • Michael Mac Manus, M.D. (F.R.C.R., F.R.A.N.Z.C.R.)

      Affiliations

    • Division of Radiation Oncology, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • Andrew Wirth, M.B. B.S. (F.R.A.C.P. F.R.A.N.Z.C.R)

      Affiliations

    • Division of Radiation Oncology, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • Gillian Duchesne, M.D. (F.R.C.R., F.R.A.N.Z.C.R.)

      Affiliations

    • Division of Radiation Oncology, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • Michael Millward, M.B. B.S. (F.R.A.C.P.)

      Affiliations

    • Division of Haematology and Medical Oncology, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • Allan McKenzie, M.B. B.S. (F.R.A.N.Z.C.R.)

      Affiliations

    • Department of Diagnostic Imaging, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • Judy Andrews, B. Appl. Sc.

      Affiliations

    • Division of Radiation Oncology, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia
  • ,
  • David Ball, M.D. (F.R.A.N.Z.C.R.)

      Affiliations

    • Corresponding Author InformationReprint requests to: David Ball, M.D., F.R.A.N.Z.C.R., Division of Radiation Oncology, Peter MacCallum Cancer Institute, Locked Bag 1, A’Beckett St., Melbourne, Victoria 8006 Australia. Tel: +61 3 9656 1111; Fax: +61 3 9656 1424
    • Division of Radiation Oncology, Peter MacCallum Cancer Institute, Melbourne, Victoria, Australia

Received 28 November 2000; received in revised form 8 February 2002; accepted 11 February 2002.

Abstract 

: To examine the interclinician variation in the definition of gross tumor volume (GTV) in patients undergoing radiotherapy for non-small-cell lung cancer (NSCLC), develop methods to minimize this variation, and test these methods.

: The radiotherapy planning computed tomography (CT) scans of 6 consecutive patients with NSCLC in which the radiologist was able to define and outline the GTV were used. Six oncologists independently contoured the tumors with the radiologist’s markings as a guide using a three-dimensional treatment planning system. Separate contours were prepared using only mediastinal window settings and using both mediastinal and lung window settings. The volumes were calculated using the planning system software (series 1). Factors that resulted in interclinician variation were determined, and, after a 3-year interval, 5 of the 6 clinicians redefined the GTVs using a revised protocol aimed at minimizing variation (series 2).

: For series 1, the interclinician variation in the measurement of volumes ranged from 5%, in the most tightly measured tumor, to 42%, in the most variable, but was, on average, 20%. Statistically significant differences were noted among the clinicians (p = 0.002), that is, some clinicians tended to record relatively small and some relatively large volumes. The reasons for the variation among the oncologists included a tendency to include regions with a low probability of containing tumor, as if the oncologist were contouring a target volume; inclusion of adjacent atelectasis (ignoring the radiologist’s outline); and variable treatment of spicules. When the exercise was repeated using the revised protocol (series 2), the degree of interclinician variation was reduced, with a range of 7–22% (average 13%). In series 2, the differences among the clinicians were not statistically significant (p = 0.25).

: Despite major radiologic input, significant variation occurred in the delineation of the three-dimensional GTVs of NSCLC among oncologists. Standardization of the approach with guidelines resulted in a reduction in this variation.

Keywords:  Non-small-cell lung cancer, Tumor volume, Three-dimensional treatment planning

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 30.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0360-3016(02)02783-9

International Journal of Radiation Oncology * Biology * Physics
Volume 53, Issue 3 , Pages 566-573, 1 July 2002