International Journal of Radiation Oncology * Biology * Physics
Volume 62, Issue 2 , Pages 426-436 , 1 June 2005

Impact of geometric uncertainties on evaluation of treatment techniques for prostate cancer

Presented in part at the 2003 Annual Meeting of the American Association of Physicists in Medicine.

  • Tim Craig, Ph.D.

      Affiliations

    • Radiation Treatment Program, London Regional Cancer Program, London Health Sciences Centre, London, ON, Canada
    • Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
    • T. Craig is currently at Radiation Medicine Program, Princess Margaret Hospital, Toronto, ON, Canada.
  • ,
  • Eugene Wong, Ph.D.

      Affiliations

    • Radiation Treatment Program, London Regional Cancer Program, London Health Sciences Centre, London, ON, Canada
    • Department of Applied Mathematics, University of Western Ontario, London, ON, Canada
    • Department of Oncology, University of Western Ontario, London, ON, Canada
  • ,
  • Glenn Bauman, M.D.

      Affiliations

    • Radiation Treatment Program, London Regional Cancer Program, London Health Sciences Centre, London, ON, Canada
    • Department of Oncology, University of Western Ontario, London, ON, Canada
  • ,
  • Jerry Battista, Ph.D.

      Affiliations

    • Radiation Treatment Program, London Regional Cancer Program, London Health Sciences Centre, London, ON, Canada
    • Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
    • Department of Oncology, University of Western Ontario, London, ON, Canada
  • ,
  • Jake Van Dyk, M.Sc.

      Affiliations

    • Radiation Treatment Program, London Regional Cancer Program, London Health Sciences Centre, London, ON, Canada
    • Department of Medical Biophysics, University of Western Ontario, London, ON, Canada
    • Department of Oncology, University of Western Ontario, London, ON, Canada
    • Corresponding Author InformationReprint requests to: Jake Van Dyk, M.Sc., Department of Physics and Engineering, London Regional Cancer Program, London Health Sciences Centre, 790 Commissioners Rd. E., London, ON N6A 4L6 Canada. Tel: (519) 685-8300, ext. 58607; Fax: (519) 685-8658

Received 23 January 2004 ,Revised 14 September 2004 ,Accepted 17 September 2004.

References 

  1. Yu C . Intensity-modulated arc therapy with dynamic multileaf collimation (An alternative to tomotherapy) . Phys Med Biol . 1995;40:1435–1449
  2. Yu CX , Li XA , Ma L , et al.   Clinical implementation of intensity-modulated arc therapy . Int J Radiat Oncol Biol Phys . 2002;53:453–462
  3. Wong E , Chen JZ , Greenland J . Intensity-modulated arc therapy simplified . Int J Radiat Oncol Biol Phys . 2002;53:222–235
  4. Bauman G , Gete E , Chen J , Wong E . Simplified intensity modulated arc therapy for dose escalated prostate radiotherapy . Med Dosim . 2004;29:18–25
  5. Kutcher GJ , Mageras GS , Leibel SA . Control, correction, and modeling of setup errors and organ motion . Semin Radiat Oncol . 1995;5:134–145
  6. Yan D , Lockman D , Brabbins D , et al.   An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer . Int J Radiat Oncol Biol Phys . 2000;48:289–302
  7. Hector CL , Webb S , Evans PM . The dosimetric consequences of inter-fractional patient movement on conventional and intensity-modulated breast radiotherapy treatments . Radiother Oncol . 2000;54:57–64
  8. Engelsman M , Damen EMF , De Jaeger K , et al.   The effect of breathing and set-up errors on the cumulative dose to a lung tumor . Radiother Oncol . 2001;60:95–105
  9. Purdy JA . Dose-volume specification (New challenges with intensity-modulated radiation therapy) . Semin Radiat Oncol . 2002;12:199–209
  10. Glatstein E . Intensity-modulated radiation therapy (The inverse, the converse, and the perverse) . Semin Radiat Oncol . 2002;12:272–281
  11. O’Dell WG , Schell MC , Reynolds D , et al.   Dose broadening due to target position variability during fractionated breath-held radiation therapy . Med Phys . 2002;29:1430–1437
  12. International Commission on Radiation Units, and Measurements . ICRU Report 50 (Prescribing, recording, and reporting photon beam therapy) . Bethesda: International Commission on Radiation Units and Measurements; 1993;
  13. Lebesque JV , Bruce AM , Kroes APG , et al.   Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer . Int J Radiat Oncol Biol Phys . 1995;33:1109–1119
  14. Lu Y , Li S , Spelbring D , et al.   Dose-surface histograms as treatment planning tool for prostate conformal therapy . Med Phys . 1995;22:279–284
  15. Dale E , Olsen DR . Regarding Ting, IJROBP 38(5) (1105–1111) . Int J Radiat Oncol Biol Phys . 1998;40:1010–1011
  16. Dale E , Olsen DR , Fossa SD . Normal tissue complication probabilities correlated with late effects in the rectum after prostate conformal radiotherapy . Int J Radiat Oncol Biol Phys . 1999;43:385–391
  17. Boersma LJ , van den Brink M , Bruce AM , et al.   Estimation of the incidence of late bladder and rectum complications after high-dose (70–78 Gy) conformal radiotherapy for prostate cancer . Int J Radiat Oncol Biol Phys . 1998;41:83–92
  18. Zelefsky MJ , Fuks Z , Leibel SA . Intensity-modulated radiation therapy for prostate cancer . Semin Radiat Oncol . 2002;12:229–237
  19. Leong J . Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation . Phys Med Biol . 1987;32:327–334
  20. Rudat V , Flentje M , Oetzel D , et al.   Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy . Radiother Oncol . 1994;33:56–63
  21. Rudat V , Schraube P , Oetzel D , et al.   Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer . Int J Radiat Oncol Biol Phys . 1996;35:1027–1034
  22. Lujan AE , Larsen EW , Balter JM , et al.   A method for incorporating organ motion due to breathing into 3D dose calculations . Med Phys . 1999;26:715–720
  23. Lujan AE , Ten Haken RK , Larsen EW , et al.   Quantization of setup uncertainties in 3-D dose calculations . Med Phys . 1999;26:2397–2402
  24. Keall PJ , Beckham WA , Booth JT , et al.   A method to predict the effect of organ motion and set-up variations on treatment plans . Australas Phys Eng Sci Med . 1999;22:48–52
  25. Lujan AE , Balter JM , Ten Haken RK . A method for incorporating organ motion due to breathing into 3D dose calculations in the liver (Sensitivity to variations in motion) . Med Phys . 2003;30:2643–2649
  26. Brock KK , McShan DL , Ten Haken RK , et al.   Inclusion of organ deformations in dose calculations . Med Phys . 2003;30:290–295
  27. van Herk M , Bruce A , Kroes APG , et al.   Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration . Int J Radiat Oncol Biol Phys . 1995;33:1311–1320
  28. Bel A , Vos PH , Rodrigus PTR , et al.   High-precision prostate cancer irradiation by clinical application of an off-line setup verification procedure using portal imaging . Int J Radiat Oncol Biol Phys . 1996;35:321–332
  29. Niemierko A , Goitein M . Implementation of a model for estimating tumor control probability for an inhomogeneously irradiated tumor . Radiother Oncol . 1993;29:140–147
  30. Fowler J , Chappell R , Ritter M . Is α/β for prostate tumors really low? . Int J Radiat Oncol Biol Phys . 2001;50:1021–1031
  31. Lyman JT , Wolbarst AB . Optimization of radiation therapy, IV (A dose-volume histogram reduction algorithm) . Int J Radiat Oncol Biol Phys . 1989;17:433–436
  32. Burman C , Kutcher GJ , Emami B , et al.   Fitting of normal tissue tolerance data to an analytic function . Int J Radiat Oncol Biol Phys . 1991;21:123–135
  33. Kutcher GJ , Burman C , Brewster L , et al.   Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations . Int J Radiat Oncol Biol Phys . 1991;21:137–146
  34. Emami B , Lyman J , Brown A , et al.   Tolerance of normal tissue to therapeutic irradiation . Int J Radiat Oncol Biol Phys . 1991;21:109–122
  35. Lee WR , Hanks GE , Hanlon AL , et al.   Lateral rectal shielding reduces late rectal morbidity following high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer (Further evidence for a significant dose effect) . Int J Radiat Oncol Biol Phys . 1996;35:251–257
  36. Ryu JK , Winter K , Michalski JM , et al.   Interim report of toxicity from 3D conformal radiation therapy (3D-CRT) for prostate cancer on 3DOG/RTOG 9406, level III (79.2 Gy) . Int J Radiat Oncol Biol Phys . 2002;54:1036–1046
  37. de Boer HCJ , Heijmen BJM . A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload . Int J Radiat Oncol Biol Phys . 2001;50:1350–1365
  38. D’Amico AV , Manola J , Loffredo M , et al.   A practical method to achieve prostate gland immobilization and target verification for daily treatment . Int J Radiat Oncol Biol Phys . 2001;51:1431–1436
  39. Litzenburg D , Dawson LA , Sandler H , et al.   Daily prostate targeting using implanted radiopaque markers . Int J Radiat Oncol Biol Phys . 2002;52:699–703
  40. Lattanzi J , McNeeley S , Pinover W , et al.   A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer . Int J Radiat Oncol Biol Phys . 1999;43:719–725
  41. Jaffray DA , Siewerdsen JH , Wong JW , et al.   Flat-panel cone-beam computed tomography for image-guided radiation therapy . Int J Radiat Oncol Biol Phys . 2002;53:1337–1349
  42. Mackie TR , Kapatoes J , Ruchala K , et al.   Image guidance for precise conformal radiotherapy . Int J Radiat Oncol Biol Phys . 2003;56:89–105
  43. Craig T , Battista J , Van Dyk J . Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance . Med Phys . 2003;30:2001–2011
  44. Craig T , Battista J , Van Dyk J . Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions . Med Phys . 2003;30:2012–2020
  45. Mageras GS , Kutcher GJ , Leibel SA , et al.   A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans . Int J Radiat Oncol Biol Phys . 1996;35:333–342
  46. Yan D , Jaffray DA , Wong JW . A model to accumulate fractionated dose in a deforming organ . Int J Radiat Oncol Biol Phys . 1999;44:665–675
  47. Fontenla E , Pelizzari CA , Roeske JC , et al.   Numerical analysis of a model of organ motion using serial imaging measurements from prostate radiotherapy . Phys Med Biol . 2001;46:2337–2358
  48. Hoogeman MS , van Herk M , Yan D , et al.   A model to simulate day-to-day variations in rectum shape . Int J Radiat Oncol Biol Phys . 2002;54:615–625
  49. Ragazzi G , Mangili P , Fiorino C , et al.   Variations of tumor control and rectum complication probabilities due to random set-up errors during conformal radiation therapy of prostate cancer . Radiother Oncol . 1997;44:259–263
  50. Li JG , Xing L . Inverse planning incorporating organ motion . Med Phys . 2000;27:1573–1578

 Supported by the Canadian Cancer Society.

PII: S0360-3016(04)02576-3

doi: 10.1016/j.ijrobp.2004.09.016

International Journal of Radiation Oncology * Biology * Physics
Volume 62, Issue 2 , Pages 426-436 , 1 June 2005