International Journal of Radiation Oncology * Biology * Physics
Volume 68, Issue 1 , Page 317, 1 May 2007

Erratum

Article Outline

 

Re: Bossi A, De Wever I, Van Limbergen E, Vanstraelen B. Intensity modulated radiation-therapy for preoperative posterior abdominal wall irradiation of retroperitoneal liposarcomas. Int J Radiat Oncol Biol Phys 2007;67:164–170.

Because of a typographical error, the dose–volume constraints reported in Table 1 of the above article were incorrect. The correct version of Table 1 appears here.

Table. Dose-volume constraints adopted for IMRT planning
Volume (%)Constraints criteria (Gy)
Planning target volume100Prescription: 50
Minimum: 48.5
Kidney, homolateral50Maximum: 20
33Maximum: 30
Kidney, contralateral50Maximum: 10
Small bowel100Maximum: 50
50Maximum: 55
Liver100Maximum: 30
33Maximum: 50
Spinal cord100Maximum: 48

PII: S0360-3016(07)00223-4

doi:10.1016/j.ijrobp.2007.01.045

Refers to article:

  • Intensity modulated radiation-therapy for preoperative posterior abdominal wall irradiation of retroperitoneal liposarcomas , 02 November 2006

    Alberto Bossi, Ivo De Wever, Erik Van Limbergen, Bianca Vanstraelen
    International Journal of Radiation Oncology * Biology * Physics 1 January 2007 (Vol. 67, Issue 1, Pages 164-170)

International Journal of Radiation Oncology * Biology * Physics
Volume 68, Issue 1 , Page 317, 1 May 2007