« PreviousNext »International Journal of Radiation Oncology * Biology * Physics
Volume 68, Issue 1 , Page 317, 1 May 2007
Volume 68, Issue 1 , Page 317, 1 May 2007
Erratum
Article Outline
Re: Bossi A, De Wever I, Van Limbergen E, Vanstraelen B. Intensity modulated radiation-therapy for preoperative posterior abdominal wall irradiation of retroperitoneal liposarcomas. Int J Radiat Oncol Biol Phys 2007;67:164–170.
Because of a typographical error, the dose–volume constraints reported in Table 1 of the above article were incorrect. The correct version of Table 1 appears here.
Table. Dose-volume constraints adopted for IMRT planning
| Volume (%) | Constraints criteria (Gy) | |
|---|---|---|
| Planning target volume | 100 | Prescription: 50 |
| Minimum: 48.5 | ||
| Kidney, homolateral | 50 | Maximum: 20 |
| 33 | Maximum: 30 | |
| Kidney, contralateral | 50 | Maximum: 10 |
| Small bowel | 100 | Maximum: 50 |
| 50 | Maximum: 55 | |
| Liver | 100 | Maximum: 30 |
| 33 | Maximum: 50 | |
| Spinal cord | 100 | Maximum: 48 |
PII: S0360-3016(07)00223-4
doi:10.1016/j.ijrobp.2007.01.045
© 2007 Elsevier Inc. All rights reserved.
Refers to article:
- Intensity modulated radiation-therapy for preoperative posterior abdominal wall irradiation of retroperitoneal liposarcomas , 02 November 2006
« PreviousNext »International Journal of Radiation Oncology * Biology * Physics
Volume 68, Issue 1 , Page 317, 1 May 2007
Volume 68, Issue 1 , Page 317, 1 May 2007