References
- Dose and volume reduction for normal lung using intensity-modulated radiotherapy for advanced-stage non-small-cell lung cancer. Int J Radiat Oncol Biol Phys. 2004;58:1258–1267
- Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer. Radiother Oncol. 2005;77:247–253
- Intensity-modulated radiation therapy for mesothelioma: Impact of multileaf collimator leaf width and pencil beam size on planning quality and delivery efficiency. Int J Radiat Oncol Biol Phys. 2005;62:1525–1534
- Dosimetric verification for intensity-modulated radiation therapy of thoracic cancers using experimental and Monte Carlo approaches. Int J Radiat Oncol Biol Phys. 2006;66:939–948
- A Monte Carlo study of radiation transport through multileaf collimators. Med Phys. 2001;28:2497–2506
- Correlation of dosimetric factors and radiation pneumonitis for non-small-cell lung cancer patients in a recently completed dose escalation study. Int J Radiat Oncol Biol Phys. 2005;63:672–682
- Investigation of clinical and dosimetric factors associated with postoperative pulmonary complications in esophageal cancer patients treated with concurrent chemoradiotherapy followed by surgery. Int J Radiat Oncol Biol Phys. 2006;64:692–699
- Fatal pneumonitis associated with intensity-modulated radiation therapy for mesothelioma. Int J Radiat Oncol Biol Phys. 2006;65:640–645
- Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields. Med Phys. 2007;34:1388–1397
- . Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose. Med Phys. 2004;31:3168–3178
- IMRT head and neck treatment planning with a commercially available Monte Carlo based planning system. Phys Med Biol. 2005;50:879–890
- Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system. Phys Med Biol. 2000;45:2483–2495
- Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer. Phys Med Biol. 2005;50:869–878
- Dose-dependent pulmonary toxicity after postoperative intensity-modulated radiotherapy for malignant pleural mesothelioma. Int J Radiat Oncol Biol Phys. 2007;69:350–357
- Development and commissioning of a multi-leaf collimator model for intensity-modulated radiation therapy. Med Phys. 2006;33:770–781
- BEAMnrc users manual. National Research Council Report PIRS-0509(A) revision G. Ottawa, Ontario, Canada: National Research Council; 2002;
- Commissioning and quality assurance of treatment planning computers. Int J Radiat Oncol Biol Phys. 1993;26:261–273
- American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: Quality assurance for clinical radiotherapy treatment planning. Med Phys. 1998;25:1773–1829
- Initial evaluation of treatment-related pneumonitis in advanced-stage non-small-cell lung cancer patients treated with concurrent chemotherapy and intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys. 2007;68:94–102
- Fatal pneumonitis associated with intensity-modulated radiation therapy for mesothelioma: In regard to Allen, et al. (Int J Radiat Oncol Biol Phys 2006;65:640-645) Int J Radiat Oncol Biol Phys. 2006;66:1595–1596author reply 1596
- Analysis of clinical and dosimetric factors associated with treatment-related pneumonitis (TRP) in patients with non-small-cell lung cancer (NSCLC) treated with concurrent chemotherapy and three-dimensional conformal radiotherapy (3D-CRT). Int J Radiat Oncol Biol Phys. 2006;66:1399–1407
Supported in part by National Cancer Institute grant R01-CA074043-08A2.
Presented at the 49th Annual Meeting of the American Association of Physicists in Medicine, July 22–26, 2007, Minneapolis, MN.
Conflict of interest: none.
PII: S0360-3016(08)00656-1
doi: 10.1016/j.ijrobp.2008.04.014
© 2008 Elsevier Inc. All rights reserved.
« Previous
Next »
International Journal of Radiation Oncology * Biology * Physics
Volume 71, Issue 5
, Pages 1537-1546
, 1 August 2008