International Journal of Radiation Oncology * Biology * Physics
Volume 72, Issue 1 , Pages 210-219 , 1 September 2008

Performance Evaluation of Automatic Anatomy Segmentation Algorithm on Repeat or Four-Dimensional Computed Tomography Images Using Deformable Image Registration Method

  • He Wang, Ph.D.

      Affiliations

    • Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Adam S. Garden, M.D.

      Affiliations

    • Department of Radiation Oncology, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Lifei Zhang, Ph.D.

      Affiliations

    • Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Xiong Wei, M.D.

      Affiliations

    • Department of Radiation Oncology, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Anesa Ahamad, M.D.

      Affiliations

    • Department of Radiation Oncology, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Deborah A. Kuban, M.D.

      Affiliations

    • Department of Radiation Oncology, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Ritsuko Komaki, M.D.

      Affiliations

    • Department of Radiation Oncology, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Jennifer O'Daniel, Ph.D.

      Affiliations

    • Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Yongbin Zhang, M.S.

      Affiliations

    • Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Radhe Mohan, Ph.D.

      Affiliations

    • Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, TX
  • ,
  • Lei Dong, Ph.D.

      Affiliations

    • Corresponding Author InformationReprint requests to: Lei Dong, Ph.D., Department of Radiation Physics, Unit 94, University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030-4009. Tel: (713) 563-2544; Fax: (713) 563-2545

Received 23 February 2008 ,Revised 5 May 2008 ,Accepted 5 May 2008.

References 

  1. Ezzell GA, Galvin JM, Low D, et al. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. Med Phys. 2003;30:2089–2115
  2. Mackie TR, Kapatoes J, Ruchala K, et al. Image guidance for precise conformal radiotherapy. Int J Radiat Oncol Biol Phys. 2003;56:89–105
  3. Court LE, Dong L. Automatic registration of the prostate for computed tomography-guided radiotherapy. Med Phys. 2003;30:2750–2757
  4. Zeidan OA, Langen KM, Meeks SL, et al. Evaluation of image-guidance protocols in the treatment of head and neck cancers. Int J Radiat Oncol Biol Phys. 2007;67:670–677
  5. Purdie TG, Bissonnette J-P, Franks K, et al. Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys. 2007;68:243–252
  6. Wang Z, Willett CG, Yin F-F. Reduction of organ motion by combined cardiac gating and respiratory gating. Int J Radiat Oncol Biol Phys. 2007;68:259–266
  7. Underberg RWM, Lagerwaard FJ, Slotman BJ, et al. Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: An analysis of 4DCT datasets. Int J Radiat Oncol Biol Phys. 2005;62:554–560
  8. Yan D, Xu B, Lockman D, et al. The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer. Int J Radiat Oncol Biol Phys. 2001;51:1111–1119
  9. Schaly B, Kempe JA, Bauman GS, et al. Tracking the dose distribution in radiation therapy by accounting for variable anatomy. Phys Med Biol. 2004;791–805
  10. Barker J, Jerry L, Garden AS, et al. Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system. Int J Radiat Oncol Biol Phys. 2004;59:960–970
  11. Jaffray DA, Siewerdsen JH, Wong JW, et al. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys. 2002;53:1337–1349
  12. Court L, Rosen I, Mohan R, et al. Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system. Med Phys. 2003;30:1198–1210
  13. Yan D, Lockman D, Martinez A, et al. Computed tomography guided management of interfractional patient variation. Semin Radiat Oncol. 2005;15:168–179
  14. Brabbins D, Martinez A, Yan D, et al. A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: Analysis of chronic toxicity. Int J Radiat Oncol Biol Phys. 2005;61:400–408
  15. Keall P. 4-Dimensional computed tomography imaging and treatment planning. Semin Radiat Oncol. 2004;14:81–90
  16. Court LE, Dong L, Lee AK, et al. An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer. Int J Radiat Oncol Biol Phys. 2005;62:154–163
  17. Mohan R, Zhang X, Wang H, et al. Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes. Int J Radiat Oncol Biol Phys. 2005;61:1258–1266
  18. Wu Q, Djajaputra D, Lauterbach M, et al. A fast dose calculation method based on table lookup for IMRT optimization. Phys Med Biol. 2003;N159–N166
  19. Pekar V, McNutt TR, Kaus MR. Automated model-based organ delineation for radiotherapy planning in prostatic region. Int J Radiat Oncol Biol Phys. 2004;60:973–980
  20. Zhang T, Chi Y, Meldolesi E, et al. Automatic delineation of on-line head-and-neck computed tomography images: Toward on-line adaptive radiotherapy. Int J Radiat Oncol Biol Phys. 2007;68:522–530
  21. Wang H, Dong L, Lii MF, et al. Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys. 2005;61:725–735
  22. Wang H, Dong L, O'Daniel J, et al. Validation of an accelerated “demons” algorithm for deformable image registration in radiation therapy. Phys Med Biol. 2005;50:2887–2905
  23. Shekhar R, Lei P, Castro-Pareja C, et al. Automatic segmentation of phase-correlated CT scans through nonrigid image registration using geometrically regularized free-form deformation. Med Phys. 2007;34:3054–3066
  24. Gonzalez RC, Woods RE. Digital image processing. Reading, MA: Addison-Wesley Publishing; 1993;
  25. Goldberg-Zimring D, Talos I-F, Bhagwat JG, et al. Statistical validation of brain tumor shape approximation via spherical harmonics for image-guided neurosurgery. Acad. Radiol. 2005;12:459–466
  26. Neumann A, Lorenz C. Statistical shape model based segmentation of medical images. Comput Med Imag Graph. 1998;22:133–143
  27. Shen D, Zhan Y, Davatzikos C. Segmentation of prostate boundaries from ultrasound images using statistical shape model. IEEE Trans Med Imag. 2003;22:539–551
  28. Rao M, Stough J, Chi Y-Y, et al. Comparison of human and automatic segmentations of kidneys from CT images. Int J Radiat Oncol Biol Phys. 2005;61:954–960
  29. Lu W, Olivera GH, Chen Q, et al. Automatic re-contouring in 4D radiotherapy. Phys Med Biol. 2006;51:1077–1099
  30. Geets X, Daisne J-F, Arcangeli S, et al. Inter-observer variability in the delineation of pharyngo-laryngeal tumor, parotid glands and cervical spinal cord: Comparison between CT-scan and MRI. Radiother Oncol. 2005;77:25–31
  31. Struikmans H, Warlam-Rodenhuis C, Stam T, et al. Interobserver variability of clinical target volume delineation of glandular breast tissue and of boost volume in tangential breast irradiation. Radiother Oncol. 2005;76:293–299
  32. Rasch C, Barillot I, Remeijer P, et al. Definition of the prostate in CT and MRI: A multi-observer study. Int J Radiat Oncol Biol Phys. 1999;43:57–66
  33. Court LE, Dong L, Taylor N, et al. Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: An intra- and interobserver study. Int J Radiat Oncol Biol Phys. 2004;59:412–418
  34. Breen SL, Publicover J, De Silva S, et al. Intraobserver and interobserver variability in GTV delineation on FDG-PET-CT images of head and neck cancers. Int J Radiat Oncol Biol Phys. 2007;68:763–770
  35. Zhang T, Orton NP, Tome WA. On the automated definition of mobile target volumes from 4D-CT images for stereotactic body radiotherapy. Med Phys. 2005;32:3493–3502
  36. Rietzel E, Chen GTY, Choi NC, et al. Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. Int J Radiat Oncol Biol Phys. 2005;61:1535–1550
  37. Brock KK, Sharpe MB, Dawson LA, et al. Accuracy of finite element model-based multi-organ deformable image registration. Med. Phys. 2005;32:1647–1659
  38. Davis B, Prigent D, Bechtel J, et al. Accommodating bowel gas in large deformation image registration for adaptive radiation therapy of the prostate. Med Phys. 2004;31:1780–1780
  39. Gao S, Zhang L, Wang H, et al. A deformable image registration method to handle distended rectums in prostate cancer radiotherapy. Med. Phys. 2006;33:3304–3312
  40. Hoogeman MS, van Herk M, Yan D, et al. A model to simulate day-to-day variations in rectum shape. Int J Radiat Oncol Biol Phys. 2002;54:615–625
  41. Yan D, Jaffray DA, Wong JW. A model to accumulate fractionated dose in a deforming organ. Int J Radiat Oncol Biol Phys. 1999;44:665–675
  42. Sharp GC, Kandasamy N, Singh H, et al. GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration. Phys Med Biol. 2007;52:5771–5787

 Supported, in part, by a sponsored research grant from Varian Medical Systems, a seed grant from the University of Texas Center for Biomedical Engineering, and Grant CA74043 from the National Cancer Institute.

 Conflict of interest: none.

PII: S0360-3016(08)00802-X

doi: 10.1016/j.ijrobp.2008.05.008

International Journal of Radiation Oncology * Biology * Physics
Volume 72, Issue 1 , Pages 210-219 , 1 September 2008