International Journal of Radiation Oncology * Biology * Physics
Volume 72, Issue 1
, Pages 261-267
, 1 September 2008
Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning
References
- . The application accuracy of stereotactic frames. Neurosurgery. 1994;35:682–694
- . Systematic analysis of errors in target localization and treatment delivery in stereotactic radiosurgery (SRS). Int J Radiat Oncol Biol Phys. 1994;28:493–498
- Patient position reproducibility in fractionated stereotactically guided conformal radiotherapy using the BrainLAB mask system. Strahlenther Onkol. 2001;177:264–268
- Intra- and interfractional patient motion for a variety of immobilization devices. Med Phys. 2005;32:3468–3474
- A simple and non-invasive vacuum mouthpiece-based head fixation system for high precision radiotherapy. Strahlenther Onkol. 2001;177:43–47
- . Repositioning accuracy of fractionated stereotactic irradiation: Assessment of isocentre alignment for different dental fixations by using sequential CT scanning. Radiother Oncol. 2005;74:61–66
- Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. Radiother Oncol. 2003;67:129–141
- . Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device. Radiother Oncol. 1995;37:153–159
- . Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiother Oncol. 2002;64:75–83
- . A phantom study on the positioning accuracy of the Novalis Body system. Med Phys. 2003;30:3052–3060
- . Setup accuracy of stereoscopic X-ray positioning with automated correction for rotational errors in patients treated with conformal arc radiotherapy for prostate cancer. Radiother Oncol. 2006;80:371–373
- . Reproducibility and treatment planning advantages of a carbon fiber relocatable head fixation system. Radiother Oncol. 2002;65:165–168
- Evaluation of intrafraction patient movement for CNS and head & neck IMRT. Med Phys. 2004;31:500–506
- . A precision cranial immobilization system for conformal stereotactic fractionated radiation therapy. Int J Radiat Oncol Biol Phys. 1995;33:1239–1245
- . Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup. Med Phys. 2007;34:2077–2084
- The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: Measurement of the repositioning accuracy. Int J Radiat Oncol Biol Phys. 2001;51:555–562
Conflict of interest: none.
PII: S0360-3016(08)00836-5
doi: 10.1016/j.ijrobp.2008.05.006
© 2008 Elsevier Inc. All rights reserved.