International Journal of Radiation Oncology * Biology * Physics
Volume 73, Issue 5 , Pages 1364-1368, 1 April 2009

Intrafraction Geometric Uncertainties in Frameless Image-Guided Radiosurgery

  • Martin J. Murphy, Ph.D.

      Affiliations

    • Corresponding Author InformationReprint requests to: Martin J. Murphy, Ph.D., Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA 23298. Tel: (804) 628-7777; Fax: (804) 628-4709

Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA

Received 14 March 2008; received in revised form 16 May 2008; accepted 17 June 2008. published online 11 December 2008.

Purpose

Frameless radiosurgery allows the possibility of intrafraction patient movement. Because radiosurgery delivers the entire radiation dose during one or a few fractions, intrafraction misalignment can result in significant underdosage of the treatment site. This article compares alignment errors and their effect on target coverage for treatments that rely only on initial (fixed) alignment vs. those that make intrafraction corrections (dynamic alignment).

Methods and Materials

This study analyzed 577 records of intrafraction patient movement observed during frameless cranial and spinal radiosurgery. For each fraction, the average misalignment per fraction was calculated. Then each fraction was divided into n minifractions and margin formulae developed for hyperfractionated radiotherapy were used to estimate the planning margin that would be necessary to preserve target coverage for the observed intrafraction movement.

Results

Dynamic alignment reduced the number of fractions with a mean misalignment greater than 2 mm from approximately 20% to nearly zero. For fixed alignment, the estimated margins for optimal target coverage were 3.6–4.5 mm for the various treatment sites. For dynamic alignment, the optimal margins were 1.2–1.6 mm.

Conclusions

The estimated margins show the large influence of systematic intrafraction shifts and the capacity of dynamic alignment to correct for them. For dynamic alignment, the margin approximately equates with the traditional precision tolerances for radiosurgery, whereas for fixed alignment, the margin is three times greater. Although these margins may not be directly applicable to radiosurgery planning, they expose the effects of intrafraction motion on target coverage.

Frameless radiosurgery, Intrafraction movement, Target alignment

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 30.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Conflict of interest: The author discloses that he has a financial interest in Accuray Incorporated, manufacturer of the CyberKnife frameless radiosurgery system.

PII: S0360-3016(08)02956-8

doi:10.1016/j.ijrobp.2008.06.1921

International Journal of Radiation Oncology * Biology * Physics
Volume 73, Issue 5 , Pages 1364-1368, 1 April 2009