« Previous
Next »
International Journal of Radiation Oncology * Biology * Physics
Volume 74, Issue 2
, Pages 567-574
, 1 June 2009
Frameless Stereotactic Body Radiotherapy for Lung Cancer Using Four-Dimensional Cone Beam CT Guidance
References
- Dose-response in stereotactic IR radiation of lung tumors. Radiother Oncol. 2005;77:83–87
- Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol. 2007;25:947–952
- Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer. Int J Radiat Oncol Biol Phys. 2008;70:685–692
- Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereo-tactic body frame. Radiother Oncol. 2000;57:225–236
- Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame. Int J Radiat Oncol Biol Phys. 2002;52:1041–1046
- Stereotactic radiotherapy for lung and liver tumors using a body cast system: setup accuracy and preliminary clinical outcome. Radiat Med. 2005;23:407–413
- Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (focal) unit. Int J Radiat Oncol Biol Phys. 2000;48:443–448
- Real-time tumour-tracking radio-therapy. Lancet. 1999;353:1331–1332
- Image guidance for precise conformal radiotherapy. Int J Radiat Oncol Biol Phys. 2003;56:89–105
- . Frameless image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system. Cancer Radiother. 2006;10:283–287
- Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys. 2002;53:1337–1349
- Respiration correlated cone beam CT. Med Phys. 2005;32:1176–1186
- Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys. 2006;65:1560–1571
- The necessity of a correct dose calculation algorithm for stereotactic lung irradiation. J Thorac Oncol. 2007;2(Suppl. 4):S752
- . Variability of four dimensional patient models. Int J Radiat Oncol Biol Phys. 2008;70:590–598
- Observer variation in target volume delineation of lung cancer related to radiation oncologist-computer interaction: A “big brother” evaluation. Radiother Oncol. 2005;77:182–190
- The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys. 2000;47:1121–1135
- The effects of target size and tissue density on the minimum margin required for random errors. Med Phys. 2004;31:3068–3079
- . A method for incorporating organ motion due to breathing into 3D dose calculations. Med Phys. 1999;26:715–720
- . Defining the PTV and PRV—new ideas about old problems. [abstract] Radiother Oncol. 2004;73(Suppl. 1):S203
- Simulation of the combined effect of delineation variation, setup error and organ motion. [abstract] Radiother Oncol. 2002;64(Suppl. 1):S115
- Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging. Int J Radiat Oncol Biol Phys. 2008;70:609–618
- Cone-beam computed tomography for on-line image guidance of lung stereotactic radio-therapy: Localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys. 2007;68:243–252
- Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol. 2006;45:897–906
- Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys. 2008;70:1045–1056
- Kilo-voltage cone beam CT setup measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device. Int J Radiat Oncol Biol Phys. 2007;68:555–561
- Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors. Radiother Oncol. 2007;83:57–64
- Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys. 2008;70:1229–1238
- Effects of respiration-induced anatomy variations on dose distributions. [abstract] Radiother Oncol. 2007;84(Suppl. 1):S75
Research partly sponsored by grants of Elekta Oncology Systems.
PII: S0360-3016(08)03268-9
doi: 10.1016/j.ijrobp.2008.08.004
© 2009 Elsevier Inc. All rights reserved.
« Previous
Next »
International Journal of Radiation Oncology * Biology * Physics
Volume 74, Issue 2
, Pages 567-574
, 1 June 2009
