« Previous
Next »
International Journal of Radiation Oncology * Biology * Physics
Volume 73, Issue 4
, Pages 1260-1269
, 15 March 2009
A Comprehensive Assessment by Tumor Site of Patient Setup Using Daily MVCT Imaging From More Than 3,800 Helical Tomotherapy Treatments
References
- . Advances in image-guided radiation therapy. J Clin Oncol. 2007;25:938–946
- Image guidance for precise conformal radiotherapy. Int J Radiat Oncol Biol Phys. 2003;56:89–105
- Tomotherapy. Semin Radiat Oncol. 1999;9:108–117
- Clinical implementation of adaptive helical tomotherapy: A unique approach to image-guided intensity modulated radiotherapy. Tech Cancer Res Treat. 2006;5:465–479
- The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes. Int J Radiat Oncol Biol Phys. 2004;60:1639–1644
- Megavoltage computed tomography imaging: A potential tool to guide and improve the delivery of thoracic radiation therapy. Clin Lung Cancer. 2004;5:303–306
- . From IMRT to IGRT: Frontierland or neverland?. Radiother Oncol. 2006;78:119–122
- . Image-guided radiotherapy is being overvalued as a clinical tool in radiation oncology. Med Phys. 2006;33:3583–3586
- . History of tomotherapy. Phys Med Biol. 2006;51:R427–R453
- Automatic registration of megavoltage to kilovoltage CT images in helical tomotherapy: An evaluation of the setup verification process for the special case of a rigid head phantom. Med Phys. 2006;33:4395–4404
- Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. Med Phys. 2005;32:2673–2681
- Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors. Int J Radiat Oncol Biol Phys. 1997;38:197–206
- Computed tomography guided management of interfractional patient variation. Semin Radiat Oncol. 2005;15:168–179
- . Errors and margins in radiotherapy. Semin Radiat Oncol. 2004;14:52–64
- . Organ motion and its management. Int J Radiat Oncol Biol Phys. 2001;50:265–278
- . Set-up error and organ motion uncertainty: A review. Australas Phys Eng Sci Med. 1999;22:29–47
- . Delineation of moving targets with slow MVCT scans: Implications for adaptive non-gated lung tomotherapy. Phys Med Biol. 2007;52:1119–1134
- The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys. 2005;61:779–788
- . The impact of daily shifts on prostate IMRT dose distributions. Med Phys. 2004;31:2845–2848
- Magnitude and clinical relevance of translational and rotational patient setup errors: A cone-beam CT study. Int J Radiat Oncol Biol Phys. 2006;65:934–942
This work was funded by National Institutes of Health National Cancer Institute Grant PO1 CA088960.
Conflict of interest: The authors T. R. Mackie and E. T. Soisson have financial interests in TomoTherapy, Inc., and therefore may have a potential conflict of interest. No other authors report potential conflicts of interest.
PII: S0360-3016(08)03832-7
doi: 10.1016/j.ijrobp.2008.11.054
© 2009 Elsevier Inc. All rights reserved.
« Previous
Next »
International Journal of Radiation Oncology * Biology * Physics
Volume 73, Issue 4
, Pages 1260-1269
, 15 March 2009
