International Journal of Radiation Oncology * Biology * Physics
Volume 77, Issue 2 , Pages 591-599 , 1 June 2010

Optimization of Collimator Trajectory in Volumetric Modulated Arc Therapy: Development and Evaluation for Paraspinal SBRT

  • Pengpeng Zhang, Ph.D.

      Affiliations

    • Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY
    • Corresponding Author InformationReprint requests to: Pengpeng Zhang, Ph.D., Memorial Sloan-Kettering Cancer Center, Medical Physics Department, 1275 York Ave., New York, NY 10065. Tel: (646)888-5616; Fax: (646)888-5626
  • ,
  • Laura Happersett, M.S.

      Affiliations

    • Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY
  • ,
  • Yingli Yang, Ph.D.

      Affiliations

    • Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY
  • ,
  • Yoshiya Yamada, M.D.

      Affiliations

    • Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY
  • ,
  • Gig Mageras, Ph.D.

      Affiliations

    • Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY
  • ,
  • Margie Hunt, M.S.

      Affiliations

    • Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY

Received 11 May 2009 ,Revised 18 August 2009 ,Accepted 20 August 2009.

References 

  1. Boyer A. Sweeping window arc therapy. Presented at the Symposium in Honor of Michael Goitein. Boston: Massachusetts; October 6, 2001;
  2. Cameron C. Sweeping-window arc therapy: An implementation of rotational IMRT with automatic beam-weight calculation. Phys Med Biol. 2005;50:4317–4336
  3. Ulrich S, Nill S, Oelfke U. Development of an optimization concept for arc-modulated cone beam therapy. Phys Med Biol. 2007;52:4099–4119
  4. Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 2008;35:310–317
  5. Crooks SM, Wu X, Takita C, et al. Aperture modulated arc therapy. Phys Med Biol. 2003;48:1333–1344
  6. Ma Y, Popple R, Suh T, Xing L. Beam's-eye view dosimetrics-guided inverse planning for aperture-modulated arc therapy. Int J Radiat Oncol Biol Phys, in press.
  7. Cozzi L, Dinshaw KA, Shrivastava SK, et al. A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol. 2008;89:180–191
  8. Kjaer-Kristoffersen F, Ohlhues L, Medin J, Korreman S. RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol. 2008;14:1–6
  9. Fogliata A, Clivio A, Nicolini G, Vanetti E, Cozzi L. Intensity modulation with photons for benign intracranial tumours: A planning comparison of volumetric single arc, helical arc and fixed gantry techniques. Radiother Oncol. 2008;89:254–262
  10. Palma D, Vollans E, James K, et al. Volumetric modulated arc therapy for delivery of prostate radiotherapy: Comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys. 2008;72:996–1001
  11. Zhang P, Happersett L, Mageras G. Volumetric modulated arc therapy: Implementation and evaluation for prostate cancer cases. Int J Radiat Oncol Biol Phys, in press, 2009.
  12. Otto K, Clark BG. Enhancement of IMRT delivery through MLC rotation. Phys Med Biol. 2002;47:3997–4017
  13. Milette MP, Otto K. Maximizing the potential of direct aperture optimization through collimator rotation. Med Phys. 2007;34:1431–1438
  14. Yamada J, Lovelock M, Bilsky MH. Image-guided intensity-modulated radiation therapy for spinal tumors. Curr Neurol Neurosci Rep. 2006;6:207–211
  15. Yamada J, Bilsky MH, Lovelock M, et al. Image-guided intensity-modulated radiation therapy for spinal tumors. Curr Neurol Neurosci Rep. 2006;6:207–211
  16. Bortfeld T, Webb S. Single-Arc IMRT?. Phys Med Biol. 2009;54:N9–N20
  17. Brahme A, Roos J-E, Lax I. Solution of an integral equation encountered in radiation therapy. Phys Med Biol. 1982;27:1221–1229
  18. Jolliffe IT. Principal component analysis. New York: Springer; 2002;
  19. Shelens J. A tutorial on principal component analysis. 2005. Available at: http://www.snl.salk.edu/∼shlens/.
  20. Spirou SV, Chui CS. A gradient inverse planning algorithm with dose–volume constraints. Med Phys. 1998;25:321–333
  21. Happersett L, Zhang P, Jackson A, et al. (2009). Volumetric modulated arc therapy for the treatment of paraspinal lesions. Presented at the American Association of Physicist in Medicine Annual Meeting, Anaheim, California.
  22. Mackie TR, Holmes T, Swerdloff S, et al. Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy. Med Phys. 1993;20:1709–1719
  23. Ling CC, Zhang P, Archambault P, et al. Commissioning and quality assurance of RapidArc™ radiotherapy delivery system. Int J Radiat Oncol Biol Phys. 2008;72:575–581
  24. Pugachev A, Xing L. Incorporating prior knowledge into beam orientation optimization in IMRT. Int J Radiat Oncol Biol Phys. 2002;54:1565–1574

 Conflict of interest: Memorial Sloan-Kettering Cancer Center has a research agreement with Varian Medical Systems.

PII: S0360-3016(09)03040-5

doi: 10.1016/j.ijrobp.2009.08.056

International Journal of Radiation Oncology * Biology * Physics
Volume 77, Issue 2 , Pages 591-599 , 1 June 2010