International Journal of Radiation Oncology * Biology * Physics
Volume 77, Issue 3 , Pages 926-931 , 1 July 2010

Standard and Nonstandard Craniospinal Radiotherapy Using Helical TomoTherapy

  • William Parker, M.Sc.

      Affiliations

    • Department of Medical Physics, McGill University Health Centre, Montreal, Quebec, Canada
    • Corresponding Author InformationReprint requests to: William Parker, M.Sc., Department of Medical Physics, McGill University Health Centre, 1650 Cedar Ave., Montreal, Quebec, Canada H3G 1A4. Tel: (514) 934-8052; Fax: (514) 934-8229
  • ,
  • Marylene Brodeur, M.Sc.

      Affiliations

    • Department of Medical Physics, McGill University Health Centre, Montreal, Quebec, Canada
  • ,
  • David Roberge, M.D.

      Affiliations

    • Department of Radiation Oncology, McGill University Health Centre, Montreal, Quebec, Canada
  • ,
  • Carolyn Freeman, M.D.

      Affiliations

    • Department of Radiation Oncology, McGill University Health Centre, Montreal, Quebec, Canada

Received 11 March 2009 ,Revised 12 August 2009 ,Accepted 4 September 2009.

References 

  1. Paulino AC. Current multimodality management of medulloblastoma. Curr Probl Cancer. 2002;26:317–356
  2. Merchant TE, Fouladi M. Ependymoma: New therapeutic approaches including radiation and chemotherapy. J Neurooncol. 2005;75:287–299
  3. Parker WA, Freeman CR. A simple technique for craniospinal radiotherapy in the supine position. Radiother Oncol. 2006;78:217–222
  4. Parker W, Filion E, Roberge D, et al. Intensity-modulated radiotherapy for craniospinal irradiation: Target volume considerations, dose constraints, and competing risks. Int J Radiat Oncol Biol Phys. 2007;69:251–257
  5. Bauman G, Yartsev S, Coad T, et al. Helical tomotherapy for craniospinal radiation. Br J Radiol. 2005;78:548–552
  6. Penagaricano JA, Papanikolaou N, Yan Y, et al. Feasibility of cranio-spinal axis radiation with the Hi-Art tomotherapy system. Radiother Oncol. 2005;76:72–78
  7. Penagaricano JA, Shi C, Ratanatharathorn V. Evaluation of integral dose in cranio-spinal axis (CSA) irradiation with conventional and helical delivery. Technol Cancer Res Treat. 2005;4:683–689
  8. Penagaricano JA, Yan Y, Corry P, et al. Retrospective evaluation of pediatric cranio-spinal axis irradiation plans with the Hi-ART tomotherapy system. Technol Cancer Res Treat. 2007;6:355–360

 Conflict of interest: none.

PII: S0360-3016(09)03213-1

doi: 10.1016/j.ijrobp.2009.09.020

International Journal of Radiation Oncology * Biology * Physics
Volume 77, Issue 3 , Pages 926-931 , 1 July 2010