Volume 76, Issue 3, Supplement , Pages S28-S35, 1 March 2010
Radiation Dose–Volume Effects of Optic Nerves and Chiasm
Publications relating radiation toxicity of the optic nerves and chiasm to quantitative dose and dose–volume measures were reviewed. Few studies have adequate data for dose–volume outcome modeling. The risk of toxicity increased markedly at doses >60 Gy at ≈1.8 Gy/fraction and at >12 Gy for single-fraction radiosurgery. The evidence is strong that radiation tolerance is increased with a reduction in the dose per fraction. Models of threshold tolerance were examined.
Optic, Nerve, Chiasm, Tolerance, Radiotherapy
Conflict of interest: none.
PII: S0360-3016(09)03284-2
doi:10.1016/j.ijrobp.2009.07.1753
© 2010 Elsevier Inc. All rights reserved.
Volume 76, Issue 3, Supplement , Pages S28-S35, 1 March 2010