International Journal of Radiation Oncology * Biology * Physics
Volume 79, Issue 5 , Pages 1580-1587 , 1 April 2011

Determination of the Absorbed Dose Rate to Water for the 18-mm Helmet of a Gamma Knife

  • Hyun-Tai Chung, Ph.D.

      Affiliations

    • Department of Neurosurgery, Seoul National University College of Medicine, Seoul, Korea
  • ,
  • Youngho Park, Ph.D.

      Affiliations

    • Department of Mechanical Engineering, Chonnam National University, Gwangju, Korea
  • ,
  • Sangil Hyun, Ph.D.

      Affiliations

    • Nanotechnology Lab, Korea Institute of Ceramic Engineering and Technology, Seoul, Korea
  • ,
  • Yongsoo Choi, Ph.D.

      Affiliations

    • Faculty of Liberal Arts and Basic Science, Hankyung National University, Anseong, Korea
  • ,
  • Gi Hong Kim, M.Sc.

      Affiliations

    • Department of Neurosurgery, Yonsei University Severance Hospital, Seoul, Korea
  • ,
  • Dong Gyu Kim, M.D., Ph.D.

      Affiliations

    • Department of Neurosurgery, Seoul National University College of Medicine, Seoul, Korea
  • ,
  • Kook Jin Chun, Ph.D.

      Affiliations

    • Center for Ionizing Radiation, Korea Research Institute of Standards and Science, Daejon, Korea
    • Department of Neurosurgery, Seoul National University College of Medicine, Seoul, Korea
    • Corresponding Author InformationReprint requests: Kook Jin Chun, Ph.D., Center for Ionizing Radiation, Korea Research Institute of Standards and Science, P.O. Box 102 Yuseong Daejon 305-340 South Korea. Tel: +8242-868-5374; Fax: +8242-868-5671

Received 22 September 2009 ,Revised 16 April 2010 ,Accepted 25 May 2010.

References 

  1. Almond PR, Biggs PJ, Coursey BM, et al. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26:1847–1870
  2. Andreo P, Burns DT, Hohlfeld K, et al. Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water. Technical Report Series no. 398 (V.11b). Vienna, Austria: IAEA; 2004;
  3. Maitz AH, Wu A, Lunsford LD, et al. Quality assurance for Gamma Knife stereotactic radiosurgery. Int J Radiat Oncol Biol Phys. 1995;32:1465–1471
  4. Chung HT. Application of IAEA TRS-398 protocol to Gamma Knife model C. J Korean Med Phys. 2007;18:194–201
  5. Meltsner SG, DeWerd LA. Air kerma based dosimetry calibration for the Leksell Gamma Knife. Med Phys. 2009;36:339–350
  6. Drzymala RE, Wood RC, Levy J. Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols. Med Phys. 2008;35:514–521
  7. Battista JJ, Rider WD, Van Dyk J. Computed tomography for radiotherapy planning. Int J Radiat Oncol Biol Phys. 1980;6:99–107
  8. IAEA International Atomic Energy Agency. Absorbed dose determination in photon and electron beams: An international code of practice. Technical Report Series no. 277. 2nd ed.. Vienna, Austria: IAEA; 1997;
  9. Seco J, Evans PM. Assessing the effect of electron density in photon dose calculations. Med Phys. 2006;33:540–552
  10. Burns JE. Definition of tissue-air ratio. Br J Radiol. 1996;(Suppl. 25):177–182
  11. Marcu SM, Wu QJ, Pillai K, et al. GammaPlan-Leksell Gamma Knife radiosurgery treatment planning verification method. Med Phys. 2000;27:2146–2149
  12. CRC Handbook of chemistry and physics. Lide DR, editor. 86th ed. London: Taylor & Francis; 2005.
  13. McKenzie AL. Cobalt-60 gamma-ray beams—Central axis depth dose data for use in radiotherapy departments. Br J Radiol. 1996;(Suppl. 25):46–61
  14. Nizin PS, Mooij RB. Tissue-air ratios for narrow 60Co gamma-ray beams. Med Phys. 1998;25:1458–1463
  15. NIST/SEMATECH. e-Handbook of Statistical Methods, http://www.itl.nist.gov/div898/ handbook/; May, 2006.
  16. Cheung JYC, Yu KN. Rotating and static sources for gamma knife radiosurgery systems: Monte Carlo studies. Med Phys. 2006;33:2500–2505
  17. Khan FM. The physics of radiation therapy. 3rd ed.. New York: Lippincott Williams & Wilkins; 2003;
  18. Hwang K, Kim JH, Baik SH. The thickness of the skull in Korean adults. J Craniofac Surg. 1999;10:395–399

 Supported by Nuclear Research & Development Program of the Korea Science and Engineering Foundation (KOSEF) grant funded by the Korean government (MEST) M800-20090066 and 20090078163.

 Conflict of interest: none.

PII: S0360-3016(10)00762-5

doi: 10.1016/j.ijrobp.2010.05.039

International Journal of Radiation Oncology * Biology * Physics
Volume 79, Issue 5 , Pages 1580-1587 , 1 April 2011